Workflow Outputs

OpenStudio-HPXML generates a number of workflow outputs:

File Notes
in.xml See HPXML Defaults. HPXML file populated with defaulted values (e.g., autosized HVAC capacities).
in.idf EnergyPlus input file.
in.osm OpenStudio model file. Only generated if the debug argument is used.
results_annual.csv (or .json or .msgpack) See Annual Outputs. Simulation annual outputs, autosized HVAC capacities and design loads, etc. in CSV or JSON format.
results_timeseries.csv (or .json or .msgpack) See Timeseries Outputs. Simulation timeseries outputs in CSV or JSON format. Only generated if requested.
results_bills.csv (or .json or .msgpack) See Utility Bill Outputs. Utility bill outputs in CSV or JSON format.
run.log Errors/warnings generated by the OpenStudio-HPXML workflow.
eplusout.* EnergyPlus output files (e.g., msgpack output, error log). Defaults to a subset of possible files; use debug to produce ALL files.

HPXML Defaults

OpenStudio-HPXML will always generate an HPXML file called in.xml, located in the run directory. This file reflects the HPXML input file provided by the user but includes any default values that OpenStudio-HPXML has used. These default values will all be tagged with the dataSource='software' attribute.

For example, suppose a central air conditioner is described in the HPXML input file like so:

<HVACPlant>
  <CoolingSystem>
    <SystemIdentifier id='CoolingSystem1'/>
    <DistributionSystem idref='HVACDistribution1'/>
    <CoolingSystemType>central air conditioner</CoolingSystemType>
    <CoolingSystemFuel>electricity</CoolingSystemFuel>
    <FractionCoolLoadServed>1.0</FractionCoolLoadServed>
    <AnnualCoolingEfficiency>
      <Units>SEER</Units>
      <Value>13.0</Value>
    </AnnualCoolingEfficiency>
  </CoolingSystem>
</HVACPlant>

The in.xml output file will include autosized HVAC capacities as well as some other details:

<HVACPlant>
  <CoolingSystem>
    <SystemIdentifier id='CoolingSystem1'/>
    <DistributionSystem idref='HVACDistribution1'/>
    <CoolingSystemType>central air conditioner</CoolingSystemType>
    <CoolingSystemFuel>electricity</CoolingSystemFuel>
    <CoolingCapacity dataSource='software'>18773.0</CoolingCapacity>
    <CompressorType dataSource='software'>single stage</CompressorType>
    <FractionCoolLoadServed>1.0</FractionCoolLoadServed>
    <AnnualCoolingEfficiency>
      <Units>SEER</Units>
      <Value>13.0</Value>
    </AnnualCoolingEfficiency>
    <SensibleHeatFraction dataSource='software'>0.73</SensibleHeatFraction>
    <extension>
      <AirflowDefectRatio dataSource='software'>0.0</AirflowDefectRatio>
      <ChargeDefectRatio dataSource='software'>0.0</ChargeDefectRatio>
      <FanPowerWattsPerCFM dataSource='software'>0.375</FanPowerWattsPerCFM>
      <CoolingAirflowCFM dataSource='software'>781.0</CoolingAirflowCFM>
    </extension>
  </CoolingSystem>
</HVACPlant>

Annual Outputs

OpenStudio-HPXML will always generate an annual output file called results_annual.csv (or results_annual.json or results_annual.msgpack), located in the run directory. The file includes the following sections of output:

Annual Energy Consumption

Annual energy consumption outputs are listed below.

Type Notes
Energy Use: Total (MBtu)  
Energy Use: Net (MBtu) Subtracts any power produced by PV (including any battery storage) or generators.

Annual Energy Consumption by Fuel Use

Fuel uses are listed below.

Type Notes
Fuel Use: Electricity: Total (MBtu)  
Fuel Use: Electricity: Net (MBtu) Subtracts any power produced by PV (including any battery storage) or generators.
Fuel Use: Natural Gas: Total (MBtu)  
Fuel Use: Fuel Oil: Total (MBtu) Includes “fuel oil”, “fuel oil 1”, “fuel oil 2”, “fuel oil 4”, “fuel oil 5/6”, “kerosene”, and “diesel”
Fuel Use: Propane: Total (MBtu)  
Fuel Use: Wood: Total (MBtu)  
Fuel Use: Wood Pellets: Total (MBtu)  
Fuel Use: Coal: Total (MBtu) Includes “coal”, “anthracite coal”, “bituminous coal”, and “coke”.

Annual Energy Consumption By End Use

End uses are listed below.

Note that all end uses are mutually exclusive – the “Electricity: Heating” end use, for example, excludes energy reported in the “Electricity: Heating Fans/Pumps” end use. So the sum of all end uses for a given fuel (e.g., sum of all “End Use: Natural Gas: *”) equal the above reported fuel use (e.g., “Fuel Use: Natural Gas: Total”).

Type Notes
End Use: Electricity: Heating (MBtu) Excludes heat pump backup and fans/pumps
End Use: Electricity: Heating Heat Pump Backup (MBtu)  
End Use: Electricity: Heating Fans/Pumps (MBtu)  
End Use: Electricity: Cooling (MBtu) Excludes fans/pumps
End Use: Electricity: Cooling Fans/Pumps (MBtu)  
End Use: Electricity: Hot Water (MBtu) Excludes recirc pump and solar thermal pump
End Use: Electricity: Hot Water Recirc Pump (MBtu)  
End Use: Electricity: Hot Water Solar Thermal Pump (MBtu) Non-zero only when using detailed (not simple) solar thermal inputs
End Use: Electricity: Lighting Interior (MBtu)  
End Use: Electricity: Lighting Garage (MBtu)  
End Use: Electricity: Lighting Exterior (MBtu) Includes exterior holiday lighting
End Use: Electricity: Mech Vent (MBtu) Excludes preheating/precooling
End Use: Electricity: Mech Vent Preheating (MBtu)  
End Use: Electricity: Mech Vent Precooling (MBtu)  
End Use: Electricity: Whole House Fan (MBtu)  
End Use: Electricity: Refrigerator (MBtu)  
End Use: Electricity: Freezer (MBtu)  
End Use: Electricity: Dehumidifier (MBtu)  
End Use: Electricity: Dishwasher (MBtu)  
End Use: Electricity: Clothes Washer (MBtu)  
End Use: Electricity: Clothes Dryer (MBtu)  
End Use: Electricity: Range/Oven (MBtu)  
End Use: Electricity: Ceiling Fan (MBtu)  
End Use: Electricity: Television (MBtu)  
End Use: Electricity: Plug Loads (MBtu) Excludes independently reported plug loads (e.g., well pump)
End Use: Electricity: Electric Vehicle Charging (MBtu)  
End Use: Electricity: Well Pump (MBtu)  
End Use: Electricity: Pool Heater (MBtu)  
End Use: Electricity: Pool Pump (MBtu)  
End Use: Electricity: Hot Tub Heater (MBtu)  
End Use: Electricity: Hot Tub Pump (MBtu)  
End Use: Electricity: PV (MBtu) Negative value for any power produced
End Use: Electricity: Generator (MBtu) Negative value for any power produced
End Use: Electricity: Battery (MBtu) Positive value for charging (including efficiency losses); negative value for discharging
End Use: Natural Gas: Heating (MBtu) Excludes heat pump backup
End Use: Natural Gas: Heating Heat Pump Backup (MBtu)  
End Use: Natural Gas: Hot Water (MBtu)  
End Use: Natural Gas: Clothes Dryer (MBtu)  
End Use: Natural Gas: Range/Oven (MBtu)  
End Use: Natural Gas: Mech Vent Preheating (MBtu)  
End Use: Natural Gas: Mech Vent Precooling (MBtu)  
End Use: Natural Gas: Pool Heater (MBtu)  
End Use: Natural Gas: Hot Tub Heater (MBtu)  
End Use: Natural Gas: Grill (MBtu)  
End Use: Natural Gas: Lighting (MBtu)  
End Use: Natural Gas: Fireplace (MBtu)  
End Use: Natural Gas: Generator (MBtu) Positive value for any fuel consumed
End Use: Fuel Oil: Heating (MBtu) Excludes heat pump backup
End Use: Fuel Oil: Heating Heat Pump Backup (MBtu)  
End Use: Fuel Oil: Hot Water (MBtu)  
End Use: Fuel Oil: Clothes Dryer (MBtu)  
End Use: Fuel Oil: Range/Oven (MBtu)  
End Use: Fuel Oil: Mech Vent Preheating (MBtu)  
End Use: Fuel Oil: Mech Vent Precooling (MBtu)  
End Use: Fuel Oil: Grill (MBtu)  
End Use: Fuel Oil: Lighting (MBtu)  
End Use: Fuel Oil: Fireplace (MBtu)  
End Use: Propane: Heating (MBtu) Excludes heat pump backup
End Use: Propane: Heating Heat Pump Backup (MBtu)  
End Use: Propane: Hot Water (MBtu)  
End Use: Propane: Clothes Dryer (MBtu)  
End Use: Propane: Range/Oven (MBtu)  
End Use: Propane: Mech Vent Preheating (MBtu)  
End Use: Propane: Mech Vent Precooling (MBtu)  
End Use: Propane: Grill (MBtu)  
End Use: Propane: Lighting (MBtu)  
End Use: Propane: Fireplace (MBtu)  
End Use: Propane: Generator (MBtu) Positive value for any fuel consumed
End Use: Wood Cord: Heating (MBtu) Excludes heat pump backup
End Use: Wood Cord: Heating Heat Pump Backup (MBtu)  
End Use: Wood Cord: Hot Water (MBtu)  
End Use: Wood Cord: Clothes Dryer (MBtu)  
End Use: Wood Cord: Range/Oven (MBtu)  
End Use: Wood Cord: Mech Vent Preheating (MBtu)  
End Use: Wood Cord: Mech Vent Precooling (MBtu)  
End Use: Wood Cord: Grill (MBtu)  
End Use: Wood Cord: Lighting (MBtu)  
End Use: Wood Cord: Fireplace (MBtu)  
End Use: Wood Pellets: Heating (MBtu) Excludes heat pump backup
End Use: Wood Pellets: Heating Heat Pump Backup (MBtu)  
End Use: Wood Pellets: Hot Water (MBtu)  
End Use: Wood Pellets: Clothes Dryer (MBtu)  
End Use: Wood Pellets: Range/Oven (MBtu)  
End Use: Wood Pellets: Mech Vent Preheating (MBtu)  
End Use: Wood Pellets: Mech Vent Precooling (MBtu)  
End Use: Wood Pellets: Grill (MBtu)  
End Use: Wood Pellets: Lighting (MBtu)  
End Use: Wood Pellets: Fireplace (MBtu)  
End Use: Coal: Heating (MBtu) Excludes heat pump backup
End Use: Coal: Heating Heat Pump Backup (MBtu)  
End Use: Coal: Hot Water (MBtu)  
End Use: Coal: Clothes Dryer (MBtu)  
End Use: Coal: Range/Oven (MBtu)  
End Use: Coal: Mech Vent Preheating (MBtu)  
End Use: Coal: Mech Vent Precooling (MBtu)  
End Use: Coal: Grill (MBtu)  
End Use: Coal: Lighting (MBtu)  
End Use: Coal: Fireplace (MBtu)  

Annual Emissions

Results for each emissions scenario defined in the HPXML file are listed as shown below. Note that rows below with values of zero will be excluded.

Type Notes
Emissions: <EmissionsType>: <ScenarioName>: Total (lb) Scenario total emissions
Emissions: <EmissionsType>: <ScenarioName>: Electricity: Total (lb) Scenario emissions for Electricity only
Emissions: <EmissionsType>: <ScenarioName>: Electricity: <EndUse> (lb) Scenario emissions for this Electricity end use only (one row per end use)
Emissions: <EmissionsType>: <ScenarioName>: Natural Gas: Total (lb) Scenario emissions for Natural Gas only
Emissions: <EmissionsType>: <ScenarioName>: Natural Gas: <EndUse> (lb) Scenario emissions for this Natural Gas end use only (one row per end use)
Emissions: <EmissionsType>: <ScenarioName>: Fuel Oil: Total (lb) Scenario emissions for Fuel Oil only
Emissions: <EmissionsType>: <ScenarioName>: Fuel Oil: <EndUse> (lb) Scenario emissions for this Fuel Oil end use only (one row per end use)
Emissions: <EmissionsType>: <ScenarioName>: Propane: Total (lb) Scenario emissions for Propane only
Emissions: <EmissionsType>: <ScenarioName>: Propane: <EndUse> (lb) Scenario emissions for this Propane end use only (one row per end use)
Emissions: <EmissionsType>: <ScenarioName>: Wood Cord: Total (lb) Scenario emissions for Wood Cord only
Emissions: <EmissionsType>: <ScenarioName>: Wood Cord: <EndUse> (lb) Scenario emissions for this Wood Cord end use only (one row per end use)
Emissions: <EmissionsType>: <ScenarioName>: Wood Pellets: Total (lb) Scenario emissions for Wood Pellets only
Emissions: <EmissionsType>: <ScenarioName>: Wood Pellets: <EndUse> (lb) Scenario emissions for this Wood Pellets end use only (one row per end use)
Emissions: <EmissionsType>: <ScenarioName>: Coal: Total (lb) Scenario emissions for Coal only
Emissions: <EmissionsType>: <ScenarioName>: Coal: <EndUse> (lb) Scenario emissions for this Coal end use only (one row per end use)

Annual Building Loads

Annual building loads are listed below.

Type Notes
Load: Heating: Delivered (MBtu) Includes HVAC distribution losses.
Load: Cooling: Delivered (MBtu) Includes HVAC distribution losses.
Load: Hot Water: Delivered (MBtu) Includes contributions by desuperheaters or solar thermal systems.
Load: Hot Water: Tank Losses (MBtu)  
Load: Hot Water: Desuperheater (MBtu) Load served by the desuperheater.
Load: Hot Water: Solar Thermal (MBtu) Load served by the solar thermal system.

Note that the “Delivered” loads represent the energy delivered by the HVAC/DHW system; if a system is significantly undersized, there will be unmet load not reflected by these values.

Annual Unmet Hours

Annual unmet hours are listed below.

Type Notes
Unmet Hours: Heating (hr) Number of hours where the heating setpoint is not maintained.
Unmet Hours: Cooling (hr) Number of hours where the cooling setpoint is not maintained.

These numbers reflect the number of hours during the heating/cooling season when the conditioned space temperature deviates more than 0.2 deg-C (0.36 deg-F) from the heating/cooling setpoint.

Peak Building Electricity

Peak building electricity outputs are listed below.

Type Notes
Peak Electricity: Winter Total (W) Winter season defined by operation of the heating system.
Peak Electricity: Summer Total (W) Summer season defined by operation of the cooling system.

Peak Building Loads

Peak building loads are listed below.

Type Notes
Peak Load: Heating: Delivered (kBtu/hr) Includes HVAC distribution losses.
Peak Load: Cooling: Delivered (kBtu/hr) Includes HVAC distribution losses.

Note that the “Delivered” peak loads represent the energy delivered by the HVAC system; if a system is significantly undersized, there will be unmet peak load not reflected by these values.

Annual Component Building Loads

Note: This section is only available if the --add-component-loads argument is used. The argument is not used by default for faster performance.

Component loads represent the estimated contribution of different building components to the annual heating/cooling building loads. The sum of component loads for heating (or cooling) will roughly equal the annual heating (or cooling) building load reported above.

Component loads disaggregated by Heating/Cooling are listed below.

Type Notes
Component Load: *: Roofs (MBtu) Heat gain/loss through HPXML Roof elements adjacent to conditioned space
Component Load: *: Ceilings (MBtu) Heat gain/loss through HPXML Floor elements (inferred to be ceilings) adjacent to conditioned space
Component Load: *: Walls (MBtu) Heat gain/loss through HPXML Wall elements adjacent to conditioned space
Component Load: *: Rim Joists (MBtu) Heat gain/loss through HPXML RimJoist elements adjacent to conditioned space
Component Load: *: Foundation Walls (MBtu) Heat gain/loss through HPXML FoundationWall elements adjacent to conditioned space
Component Load: *: Doors (MBtu) Heat gain/loss through HPXML Door elements adjacent to conditioned space
Component Load: *: Windows (MBtu) Heat gain/loss through HPXML Window elements adjacent to conditioned space, including solar
Component Load: *: Skylights (MBtu) Heat gain/loss through HPXML Skylight elements adjacent to conditioned space, including solar
Component Load: *: Floors (MBtu) Heat gain/loss through HPXML Floor elements (inferred to be floors) adjacent to conditioned space
Component Load: *: Slabs (MBtu) Heat gain/loss through HPXML Slab elements adjacent to conditioned space
Component Load: *: Internal Mass (MBtu) Heat gain/loss from internal mass (e.g., furniture, interior walls/floors) in conditioned space
Component Load: *: Infiltration (MBtu) Heat gain/loss from airflow induced by stack and wind effects
Component Load: *: Natural Ventilation (MBtu) Heat gain/loss from airflow through operable windows
Component Load: *: Mechanical Ventilation (MBtu) Heat gain/loss from airflow/fan energy from mechanical ventilation systems (including clothes dryer exhaust)
Component Load: *: Whole House Fan (MBtu) Heat gain/loss from airflow due to a whole house fan
Component Load: *: Ducts (MBtu) Heat gain/loss from conduction and leakage losses through supply/return ducts outside conditioned space
Component Load: *: Internal Gains (MBtu) Heat gain/loss from appliances, lighting, plug loads, water heater tank losses, etc. in the conditioned space

Annual Hot Water Uses

Annual hot water uses are listed below.

Type Notes
Hot Water: Clothes Washer (gal)  
Hot Water: Dishwasher (gal)  
Hot Water: Fixtures (gal) Showers and faucets.
Hot Water: Distribution Waste (gal)  

HVAC Capacities

System outputs are listed below. Autosized HVAC systems are based on HVAC design temperatures/loads described below. Capacities for individual HVAC systems can be found in the in.xml file.

Type Notes
HVAC Capacity: Cooling (Btu/h) Total HVAC cooling capacity
HVAC Capacity: Heating (Btu/h) Total HVAC heating capacity
HVAC Capacity: Heat Pump Backup (Btu/h) Total HVAC heat pump backup capacity

HVAC Design Temperatures

Design temperatures are used in the design load calculations for autosizing of HVAC equipment. 1%/99% design temperatures are obtained from the DESIGN CONDITIONS header section inside the EPW weather file. If they are not available in the EPW header, the design temperatures are calculated from the 8760 hourly temperatures in the EPW. Design temperatures can also be found in the in.xml file.

Type Notes
HVAC Design Temperature: Heating (F) 99% heating drybulb temperature
HVAC Design Temperature: Cooling (F) 1% cooling drybulb temperature

HVAC Design Loads

Design load outputs, used for autosizing of HVAC equipment, are listed below. Design loads are based on block load ACCA Manual J calculations using 1%/99% design temperatures. Design loads can also be found in the in.xml file.

Type Notes
HVAC Design Load: Heating: Total (Btu/h) Total heating design load
HVAC Design Load: Heating: Ducts (Btu/h) Heating design load for ducts
HVAC Design Load: Heating: Windows (Btu/h) Heating design load for windows
HVAC Design Load: Heating: Skylights (Btu/h) Heating design load for skylights
HVAC Design Load: Heating: Doors (Btu/h) Heating design load for doors
HVAC Design Load: Heating: Walls (Btu/h) Heating design load for walls
HVAC Design Load: Heating: Roofs (Btu/h) Heating design load for roofs
HVAC Design Load: Heating: Floors (Btu/h) Heating design load for floors
HVAC Design Load: Heating: Slabs (Btu/h) Heating design load for slabs
HVAC Design Load: Heating: Ceilings (Btu/h) Heating design load for ceilings
HVAC Design Load: Heating: Infiltration/Ventilation (Btu/h) Heating design load for infiltration/ventilation
HVAC Design Load: Cooling Sensible: Total (Btu/h) Total sensible cooling design load
HVAC Design Load: Cooling Sensible: Ducts (Btu/h) Sensible cooling design load for ducts
HVAC Design Load: Cooling Sensible: Windows (Btu/h) Sensible cooling design load for windows
HVAC Design Load: Cooling Sensible: Skylights (Btu/h) Sensible cooling design load for skylights
HVAC Design Load: Cooling Sensible: Doors (Btu/h) Sensible cooling design load for doors
HVAC Design Load: Cooling Sensible: Walls (Btu/h) Sensible cooling design load for walls
HVAC Design Load: Cooling Sensible: Roofs (Btu/h) Sensible cooling design load for roofs
HVAC Design Load: Cooling Sensible: Floors (Btu/h) Sensible cooling design load for floors
HVAC Design Load: Cooling Sensible: Slabs (Btu/h) Sensible cooling design load for slabs
HVAC Design Load: Cooling Sensible: Ceilings (Btu/h) Sensible cooling design load for ceilings
HVAC Design Load: Cooling Sensible: Infiltration/Ventilation (Btu/h) Sensible cooling design load for infiltration/ventilation
HVAC Design Load: Cooling Sensible: Internal Gains (Btu/h) Sensible cooling design load for internal gains
HVAC Design Load: Cooling Latent: Total (Btu/h) Total latent cooling design load
HVAC Design Load: Cooling Latent: Ducts (Btu/h) Latent cooling design load for ducts
HVAC Design Load: Cooling Latent: Infiltration/Ventilation (Btu/h) Latent cooling design load for infiltration/ventilation
HVAC Design Load: Cooling Latent: Internal Gains (Btu/h) Latent cooling design load for internal gains

Timeseries Outputs

OpenStudio-HPXML can optionally generate a timeseries output file. The timeseries output file is called results_timeseries.csv (or results_timeseries.json or results_timeseries.msgpack) and located in the run directory.

Depending on the outputs requested, the file may include:

Type Notes
Total Consumptions Energy use for building total.
Fuel Consumptions Energy use for each fuel type (in kBtu for fossil fuels and kWh for electricity).
End Use Consumptions Energy use for each end use type (in kBtu for fossil fuels and kWh for electricity).
Emissions Emissions (e.g., CO2) for each scenario defined in the HPXML file.
Emission Fuels Emissions (e.g., CO2) disaggregated by fuel type for each scenario defined in the HPXML file.
Emission End Uses Emissions (e.g., CO2) disaggregated by end use for each scenario defined in the HPXML file.
Hot Water Uses Water use for each end use type (in gallons).
Total Loads Heating, cooling, and hot water loads (in kBtu) for the building.
Component Loads Heating and cooling loads (in kBtu) disaggregated by component (e.g., Walls, Windows, Infiltration, Ducts, etc.).
Unmet Hours Heating and cooling unmet hours.
Zone Temperatures Zone temperatures (in deg-F) for each space (e.g., living space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints.
Airflows Airflow rates (in cfm) for infiltration, mechanical ventilation (including clothes dryer exhaust), natural ventilation, whole house fans.
Weather Weather file data including outdoor temperatures, relative humidity, wind speed, and solar.
EnergyPlus Output Variables These are optional and can be requested with the ReportSimulationOutput user_output_variables argument.

Timeseries outputs can be one of the following frequencies: hourly, daily, monthly, or timestep (i.e., equal to the simulation timestep, which defaults to an hour but can be sub-hourly).

Timestamps in the output use the start-of-period convention unless you have requested the end-of-period timestamp convention. Additional timestamp columns can be optionally requested that reflect daylight saving time (DST) and/or coordinated universal time (UTC). Most outputs will be summed over the hour (e.g., energy) but some will be averaged over the hour (e.g., temperatures, airflows).

Utility Bill Outputs

OpenStudio-HPXML can optionally generate a utility bills output file. The utility bills output file is called results_bills.csv (or results_bills.json or results_bills.msgpack) and located in the run directory.

Results for each utility bill scenario defined in the HPXML file are listed as shown below. Note that rows below with values of zero will be excluded.

Type Notes
<ScenarioName>: Total ($) Scenario annual total charges.
<ScenarioName>: Electricity: Fixed ($) Scenario annual fixed charges for electricity.
<ScenarioName>: Electricity: Energy ($) Scenario annual energy charges for electricity.
<ScenarioName>: Electricity: PV Credit ($) Scenario annual production credit (negative value) for PV.
<ScenarioName>: Electricity: Total ($) Scenario annual total charges for electricity.
<ScenarioName>: Natural Gas: Fixed ($) Scenario annual fixed charges for natural gas.
<ScenarioName>: Natural Gas: Energy ($) Scenario annual energy charges for natural gas.
<ScenarioName>: Natural Gas: Total ($) Scenario annual total charges for natural gas.
<ScenarioName>: Fuel Oil: Fixed ($) Scenario annual fixed charges for fuel oil.
<ScenarioName>: Fuel Oil: Energy ($) Scenario annual energy charges for fuel oil.
<ScenarioName>: Fuel Oil: Total ($) Scenario annual total charges for fuel oil.
<ScenarioName>: Propane: Fixed ($) Scenario annual fixed charges for propane.
<ScenarioName>: Propane: Energy ($) Scenario annual energy charges for propane.
<ScenarioName>: Propane: Total ($) Scenario annual total charges for propane.
<ScenarioName>: Wood Cord: Fixed ($) Scenario annual fixed charges for wood cord.
<ScenarioName>: Wood Cord: Energy ($) Scenario annual energy charges for wood cord.
<ScenarioName>: Wood Cord: Total ($) Scenario annual total charges for wood cord.
<ScenarioName>: Wood Pellets: Fixed ($) Scenario annual fixed charges for wood pellets.
<ScenarioName>: Wood Pellets: Energy ($) Scenario annual energy charges for wood pellets.
<ScenarioName>: Wood Pellets: Total ($) Scenario annual total charges for wood pellets.
<ScenarioName>: Coal: Fixed ($) Scenario annual fixed charges for coal.
<ScenarioName>: Coal: Energy ($) Scenario annual energy charges for coal.
<ScenarioName>: Coal: Total ($) Scenario annual total charges for coal.